- 16 bit A/D converter board
- 8 synchronous channels with seperate A/D
- Maximum sampling rate 250 kS/s on 8 channels
- Extremely high dynamic range
- Up to 256 MSample memory
- 8 input ranges between ±50 mV and ±10 V
- Continuous FIFO mode
- Automatic offset calibration
- Synchronisation to multi-board system possible
- 32 Bit PXI interface
- Compatible with 3,3V and 5V PCI I/O-Voltage

MX.47xx FamilyThe MX.47xx for the first time offers full 16 bit resolution synchronously on eight channels at high sampling rates. Every channel has its own amplifier and A/D converter. This eliminates the problems known from multiplexed systems like phase error between the channels or high crosstalk. Every input channel can be offset and gain calibrated by software using a highprecision onboard calibration source. Three different models are available, each in a different speed grade. These versions are working with sampling rates of 100 kS/s, 250 kS/s or 500 kS/s. The boards can also be updated to a multi-channel system using the PXI backplane signals. Model | 1 channel | 2 channels | 4 channels | 8 channels | | 100 kS/s | 100 kS/s | 100 kS/s | 100 kS/s | | 250 kS/s | 250 kS/s | 250 kS/s | 250 kS/s | | 500 kS/s | 500 kS/s | 500 kS/s | 500 kS/s |
Memory | FIFO Mode: continous data transfer up to 100 MB/s [ more...] |
 | Ringbuffer: Recording with Pre- and Posttrigger [ more...] |
 | Standard memory 8 MSamples |
 | Option memory upgrade to 16 MS, 32 MS or 64 MS on-board memory |
Trigger | Channel Trigger: Recognition of level and edge [ more...] |
 | Window Trigger: Trigger at window enter or leave [ more...] |
 | Pulsewidth Trigger: Trigger on defined pulsewidth [ more...] |
 | OR Conjunction: Several trigger sources are or'd [ more...] |
 | Steepness trigger between two levels [ more...] |
 | External Trigger: Input or output of external TTL signal [ more...] |
 | Option Multiple Recording: Recording of trigger events with high repetition rates and very small dead time [ more...] |
 | Option Gated Sampling: Recording controlled by gate signal [ more...] |
Clock | External Clock: Input or output of sampling clock [ more...] |
 | Reference Clock: Used to generate sampling clock [ more...] |
PXI BusThe PXI bus extension offers a lot of pre-defined lines on the backplane for clock and trigger synchronisation between different boards.
The Spectrum card supports these PXI features:  | 10 MHz Reference Clock: Could be used as base for samplerate generation |
 | Star Trigger: supported as trigger source for the board |
 | Trigger Bus: Direct card synchronisation with the integrated trigger bus |
Software Support | Standard drivers for Windows and Linux as well as examples for C/C++, Delphi and Basic are included in the delivery [ more...] |
 | Firmware update in the Spectrum Control Center[ more...] |
 | SBench 5: Comfortable measurement software for windows [ more...] |
 | Option LabVIEW drivers: Libraries and examples for LabVIEW[ more...] |
 | Option DASYLab driver: Direct access to cards with DASYLab [ more...] |
 | Option MATLAB driver: Universal driver for all cards [ more...] |
 | Option VEE driver: Libraries and examples for Agilent VEE [ more...] |
DownloadsApplication Notes
|